Continuous Monitoring Device Hardware for InsightCM

Overview

Cutsforth Continuous Monitoring Devices, such as Condition Monitoring Systems (CMS) and Motor Current Signature Analysis (MCSA) systems, are NI CompactRIO-based systems that are composed of the following hardware and software components: CompactRIO controller, NI C Series I/O modules installed in the chassis, and InsightCM device software application image. InsightCM supports a sub-set of the CompactRIO hardware platform when using the standard product. This document details the supported hardware for the standard product.

Controllers

Cutsforth Monitoring Devices run InsightCM device software, referred to as application images. Each device type has a specific application image, and application images cause the device to perform operations such as acquiring data, collecting files, and communicating with InsightCM Server. The application image names refer to the device type and are used in this document to indicate the target monitoring type.

Application

InsightCM Application Image

Controller

Condition Monitoring

CMS-9047

cRIO-9047

 

CMS-9036*

cRIO-9036*

 

CMS-9058

cRIO-9058

 

CMS-9055

cRIO-9055

 

CMS-9068*

cRIO-9068*

 

CMS-9065*

cRIO-9065*

MCSA

MMS-9042

cRIO-9042

 

MMS-9047

cRIO-9047

 

MMS-9058

cRIO-9058

 

MMS-9055

cRIO-9055

 

MMS-9068*

cRIO-9068*

 

MMS-9065*

cRIO-9065*

Thermal Imaging

IR-9042

cRIO-9042

 

IR-9055

cRIO-9055

 

Xi 410

 

 

IR-3120*

IC-3120*

Table 1. Supported CompactRIO Controllers

Vibration and General Condition Monitoring Modules

The CMS-9047, CMS-9036*, CMS-9058, CMS-9055, CMS-9068*, and CMS-9065* are general purpose condition monitoring devices.

The CMS-9047 and CMS-9036* are the high-performance device options. They only supports dynamic signal acquisition (DSA) modules in all eight slots and requires that module slots 1 and 2 are filled. Module 1 must use a NI-9232 for tachometer reading, and modules slots 2-8 can be either NI-9232 or NI-9230. The CMS-9036* (IEPE Disabled) is a variant image of the CMS-9036* that disables IEPE on all channels. The CMS-9036* (IEPE Disabled) and CMS-9047 (IEPE Disabled) supports the NI-9229 in module slots 2-8.

The CMS-9058, CMS-9055, CMS-9068*, and CMS-9065* are the standard CMS devices. These devices support DSA modules for waveform acquisition and single-point, static modules for process, static, and digital inputs. The module configuration for these devices require specific module layouts in the chassis.

Module

Description

Sampling

Comment

NI 9230

3-channel DSA +/- 30 V, IEPE

12.8 kS/s/channel

 

NI 9232

3-channel DSA +/- 30 V, IEPE

102.4 kS/s/channel

 

NI 9229

4-channel DSA +/- 60 V

51.2 kS/s/channel

CMS-9036* (IEPE Disabled) and CMS-9047 (IEPE Disabled) Support Only

Table 2. Supported DSA Modules

Module

Description 

Accessories

Static Voltage

NI 9205

16-channel, differential, ±10 V

NI 9940 (spring terminals optional strain relief), NI 9923 (front mount D-Sub)

NI 9207

8-channel, ±10 V

(also with 8-channel current, 4-20 mA)

NI 9940 (sprint terminals optional strain relief), NI 9923 (front mount D-Sub)

NI 9229

High-isolation, 4-channel differential, ±60V

NI 9971 (optional strain relief)

NI 9239

High-isolation, 4-channel differential, ±10V

NI 9971 (optional strain relief)

Current

NI 9207

8-channel, 4-20 mA

(also with 8-channel voltage, ±10V)

NI 9940 (sprint terminals optional strain relief), NI 9923 (front mount D-Sub)

NI 9208

16-channel, 4-20 mA

NI 9940 (sprint terminals optional strain relief), NI 9923 (front mount D-Sub)

Temperature

NI 9211

4-channel, thermocouple

NI 9932 (optional strain relief)

NI 9213

16-channel, thermocouple

NI 9940 (sprint terminals optional strain relief), NI 9940 (optional strain relief)

NI 9214

16-channel, high-accuracy thermocouple

 

NI 9216

8-channel, PT100 RTD

NI 9940 (spring terminals optional strain relief), NI 9923 (front mount D-Sub)

NI 9217

4-channel, PT100 RTD

NI 9939 (optional strain relief)

NI 9226

8-channel, PT1000 RTD

NI 9940 (spring terminals optional strain relief), NI 9923 (front mount D-Sub)

Digital Input

NI 9425

32-channel, sinking (contact closure)

NI 9940 (sprint terminals optional strain relief), NI 9923 (front mount D-Sub)

NI 9426

32-channel, sourcing (contact closure)

NI 9923 (front mount D-Sub)

Miscellaneous

NI 9219

4-channel universal support for V, mA, Ω, open contact, thermocouple, and RTD

NI 9972 (optional strain relief)

Table 3. Supported Static Modules

MCSA Modules

The MMS-9058, MMS-9055, MMS-9068*, and MMS-9065* are the motor current signature analysis devices. These devices offer monitoring of multiple two-phase or three-phase AC induction electric motors on a single voltage bus using MCSA. Both device types are functionally equivalent but differ in the number of slots available for C Series modules (MMS-9068* has eight slots, and MMS-9065* has four slots). The MCSA devices require that module slots 1 and 2 are filled. Module 1 must use a NI-9242 for voltage bus measurement, and other modules slots are NI 9239 for current measurement on specific motors. Module slots must be filled in ascending order, but not all slots need to be filled.

Module

Description

Sampling

NI 9242

3-channel, 250 Vrms Potential Transducer Input

5-10 kS/s/channel

NI 9239

4-channel, +/- 10 V Current Transducer Input

5-10 kS/s/channel

Table 4. Supported MSCA Modules

Thermal Imaging Cameras

The new compact infrared camera Optris Xi 410 combines the benefits of infrared cameras and infrared thermometers. The Xi 410 has a fast Ethernet interface and can be powered by PoE. This allows for a simple installation, even if the distance from the PC is large. The built-in hot spot finder function can be used to reliably measure moving objects without having to reposition the camera. If the network connection is interrupted or if the connected PC has a problem, the camera immediately switches to the autonomous stand-alone mode which ensures a continuous measurement and alarm. Thus, the reliability of problem detection (typically exceeding a threshold in the context of monitoring a fire outbreak) is maintained.

Camera

Description

Comment

Xi 410

Optris IR Camera

Contact your Application Specialist for more information.

Ax5 Series*

FLIR IR Camera*

Table 5. Supported Thermal Cameras

*Indicates legacy equipment

Do you need more help?

Submit your questions or requests using the Support Ticket Submission form.

Was this article helpful?