IT System Requirements

Overall Architecture

The Wired Vibration Monitoring system uses an InsightCM edge hardware data acquisition device (cRIO) to acquire vibration signals at the field level. Processed data and extracted features are transmitted via TCP over an Ethernet network to the InsightCM server application, which provides data storage, trending, alarming, and data-viewer access. The server can be connected to the plant historian and to business-network users via HTTPS.

Server Hardware Requirements

Note

InsightCM requires a dedicated server. If NI SystemLink is present on the target machine (for example, from a previous NI deployment), install InsightCM on a different server, as the two products cannot share a machine.

Note

Cutsforth recommends using solid state drives to improve disk throughput.

Networking Requirements

A fast or gigabit Ethernet connection (100 Mbps or 1000 Mbps) is required between the InsightCM server and the Wired Vibration Monitoring devices. It is also preferable for the server to be connected to the site data historian to enable process data integration.

Hardware Specifications

Power Requirements

Parameter

Specification

Plant-supplied power source

120 V, 60 Hz or 240 V, 50 Hz

Input voltage range

85 – 264 VAC

Input frequency range

47 – 63 Hz

Input power rating

150 W

Maximum power consumption

120 W

Internal circuit breaker

120 V, 5 A

Input wire connection type

DIN, Screw-Down Terminal Block

Input wire size

26 – 10 AWG

Overvoltage category

III; per EN62368, EN61558, EN50178, EN60664-1, EN62477-1

Environmental Specifications

Parameter

Specification

Operating temperature

-40 °C to 60 °C (-40 °F to 140 °F)

Storage temperature

-40 °C to 85 °C (-40 °F to 185 °F)

Operating humidity

10% RH to 90% RH, non-condensing

Storage humidity

5% RH to 95% RH, non-condensing

Maximum altitude

5,000 m (16,400 ft)

Enclosure Specifications

Parameter

Specification

Catalog number

SNB-3746

Dimensions

20.0 in. × 16.0 in. × 8.0 in. (508 mm × 406 mm × 203 mm)

UL listing

UL 508A Listed Type 1, 2, 4, 4X, 12, 13 — File No. E194432

IP rating

IP65 and IP66

Construction

Powder coated steel; RoHS compliant

Note

Conduit holes are not pre-drilled. Conduit sizing and hole placement are customizable per installation.

Was this article helpful?
0 out of 0 found this helpful