The Rotor Flux Monitoring system tracks the magnetic flux within a generator. Variances in magnetic flux indicate deterioration of winding insulation. Whether a result of thermal wear, large variation on load, contamination, or other causes, the impact to efficient generation is significant. Imbalances within the rotor damages insulation, which in turn degrades the generator’s output capacity and increases vibrations, further damaging the insulation, which ultimately leads to a forced outage. Once the monitoring system collects the rotor flux data from the probe, the data is then ported directly into Cutsforth's InsightCM online asset monitoring software for viewing and alarm setting in the control room or any authorized remote location.

Key Specifications

Rotor Flux:

  • 0-10 V 0-Pk

  • Signal acquisition rate: 50kS/

Isolation: 1500 V

Accuracy: ± 1 V and 5% of current in specified range

Operating Temperature: -40°C to 70°C (-40°F to 158°F)

Technical Specifications

Monitoring System Enclosure

Catalog Number

Dimensions (in. (mm))

Stainless Steel Type

CSD16168SS6-MODS

16.0 (406) x 16.0 (406) x 8.0 (203)

316

EnclosureSpecifications-2078.png

Specifications:

  • UL 508A Listed; Type 3R, 4, 4X, 12; File No. E61997

  • cUL Listed per CSA C22.2 No 94; Type 3R, 4, 4X, 12; File No. E61997

  • NEMA/EEMAC Type 3R, 4, 4X, 12, 13

  • CSA File No. 42186: Type 4, 4X, 12

  • VDE IP66

  • IEC 60529, IP66

  • Meets NEMA Type 3RX requirements

EXMC-002: Optional sunshield for outdoor installations

EXMC-002

AC Power Supply Requirements

Plant-supplied Power Source

120 V, 60 Hz AC or 240 V, 50 Hz AC

Circuit Breaker

Internal 120 V, 5 A

Circuit Draw Under Normal Usage

Approximately 0.6 A

Digitizers

NI-9215

Range

± 10 V

Sample Rate

100 kS/s

Resolution

16-bit

Manufacturer's Datasheet

http://www.ni.com/pdf/manuals/373779a_02.pdf

Safety Standard

This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:

  • IEC 61010-1, EN 61010-1

  • UL 61010-1, CSA 61010-1

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:

EN 61326 (IEC 61326)

Class A emissions; Basic immunity

EN 55011 (CISPR 11)

Group 1, Class A emissions

AS/NZS CISPR 11

Group 1, Class A emissions

FCC 47 CFR Part 15B

Class A emissions

ICES-001

Class A emissions

CE Compliance

Meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 2006/95/EC, Low-Voltage Directive (safety); 2004/108/EC, Electromagnetic Compatibility Directive (EMC)

Environmental

Storage Temperature

-40 °C to 85 °C (-40 °F to 185 °F)

Operating Temperature

-40 °C to 70 °C (-40 °F to 158 °F)

Storage Humidity

5% RH to 95% RH, noncondensing

Operating Humidity

10% RH to 90% RH, noncondensing

Maximum Altitude

5,000 m (16,400 ft)

Was this article helpful?
0 out of 0 found this helpful