Related Products:

EGSA-013, EGSA-015, EGSA-210, EGSA-220, EAMA-001, EAMA-003

Related Documents:

EZDP-2100

Type:

operations, reference information

Keywords/Labels:

shaft voltage RMS output, exciter shaft voltage RMS output, ground current RMS output, unit status,

Summary:

This topic provides output values for shaft voltage, exciter shaft voltage, and ground current RMS.

4-20 mA Lines

Shaft Voltage RMS Output Values

Shaft Voltage (V)

Conditioned Voltage (V)

4-20 mA Output

0

0

4

25

2.5

8

50

5

12

75

7.5

16

100

10

20

 

Exciter Shaft Voltage RMS Output Values

Shaft Voltage (V)

Conditioned Voltage (V)

4-20 mA Output

0

0

4

25

2.5

8

50

5

12

75

7.5

16

100

10

20

 

Ground Current RMS Output Values

Shaft Voltage (V)

Conditioned Voltage (V)

4-20 mA Output

0

0

4

12.5

2.5

8

25

5

12

37.5

7.5

16

50

10

20

 

Unit Status

In the following table, the shaded cells apply only when the optional Exciter Shaft Contact Assembly (SCA) is installed.

4-20 mA Output (± 0.5 mA)

Condition

Description or Recommended Action

4

Normal, generator online

Alert: Generator online. Not a fault condition.

 

SGA ground rope

SGA meter rope

SCA exciter rope

6-12 mA = Rope status array

6

Stepped Up

Normal

Normal

Rope Fault: SGA ground rope

7

Normal

Stepped Up

Normal

Rope Fault: SGA meter rope

8

Normal

Normal

Stepped Up

Rope Fault: SCA exciter rope

9

Stepped Up

Stepped Up

Normal

Rope Fault: SGA ground rope and SGA meter rope

10

Stepped Up

Normal

Stepped Up

Rope Fault: SGA ground rope and SCA exciter rope

11

Normal

Stepped Up

Stepped Up

Rope Fault: SGA meter rope and SCA exciter rope

12

Stepped Up

Stepped Up

Stepped Up

Rope Fault: SGA ground rope, SGA meter rope, and SCA exciter rope

13 - 20

Not a valid output.

 

 
 

Do you need more help?

 
 
Was this article helpful?