Related Products:

EGSA-013, EGSA-015, EGSA-210, EGSA-220, EGSA-310, EGSA-320, EAMA-001, EAMA-003, EAMA-005

Related Documents:

EZDP-2100, EZDP-2104

Type:

Troubleshooting

Keywords/Labels:

grounding rope, metering rope

Summary:

This document describes how to troubleshoot SGA ropes.

Shaft Grounding Assembly (SGA) Ropes

The SGA contains two ropes. Both ropes provide grounding and are named as indicated in the figure below.

The grounding rope (A) acts as the primary direct connection between the generator shaft and the unit case.

The metering rope (B) connects the shaft to the unit case through a small resistor to facilitate measuring shaft voltage in addition to providing a secondary connection to ground. The metering rope also provides temporary primary grounding when the grounding rope is being replaced or is not connected to the shaft for any reason.

Series 1

Series 2 and 3

Series1-SGA.png
Series2-3-SGA.png
 

Do you need more help?

 
 
Was this article helpful?
0 out of 0 found this helpful