Monitored Lines, Bandwidths, and Calculating Average and Peak Values (EZDP-2089 and EZDP-2104)

Related Products:

EAMA-001, EAMA-002, EAMA-003, EAMA-004, EAMA-005, EAMA-210, EGSA-310, EGSA-320, EXMC-001

Related Documents:

EZDP-2089, EZDP-2104

Type:

operations, reference information

Keywords/Labels:

lines, bandwidths, average values, peak values

Summary:

This topic provides reference information on monitored lines and bandwidths and how to calculate average and peak values.

Reference Information

This section provides detailed technical information on the Generator Field Monitoring System capabilities and legal information.

Monitored Lines and Bandwidths

Standard Data Collection

Monitored Line

Bandwidth

Attenuation Ratio

Ground Current

1 MS/s or 222 kHz

30 A : 10 V

Shaft Voltage

1 MS/s or 222 kHz

100 V : 10 V

Exciter Shaft Voltage

1 MS/s or 222 kHz

100 V : 10 V

Meter Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Ground Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Exciter Meter Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Rotor Flux

100 kS/s or 22.2 kHz

100 V : 10 V

Burst Mode

Monitored Line

Bandwidth

Attenuation Ratio

Ground Current

20 MS/s or 500 kHz

30 A : 10 V

Shaft Voltage

20 MS/s or 500 kHz

100 V : 10 V

Exciter Shaft Voltage

20 MS/s or 500 kHz

100 V : 10 V

Meter Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Ground Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Exciter Meter Rope Wear Indicator

100 kS/s or 22.2 kHz

100 V : 10 V

Rotor Flux

100 kS/s or 22.2 kHz

100 V : 10 V

 

How Average and Peak Values Are Calculated

  • Average voltages and currents are calculated on the samples taken during each snapshot as the sum of (x)/N, where x is the array of samples acquired, and N is the number of samples.

  • Zero-to-peak voltages and currents are calculated on the samples taken during each 0.02 second period by the following formula:

    Peak-Values-1-2080.png
  • The longer-term averages are calculated by accumulating averages for the specified period. They are then reset in preparation for the next calculation. The formula used is as follows:

    Peak-Values-2-2080.png
 
 

Do you need more help?

 
 
Was this article helpful?
0 out of 0 found this helpful