Modbus registers for two generators that each have 6 slots per pole.

Modbus Registers

The Modbus registers shown below are for two generators that each have 6 slots per pole. The actual number of registers varies depending on the number of slots, which explains the gaps between groups of values, such as Gen 1 starting at register number 0 and Gen 2 starting at register number 1000.

Note

The Input registers are single precision floating point values.

Table 1. Input Registers

Gen 1 Lead 1

0

Input

Gen 1 Lead 2

2

Input

Gen 1 Lead 3

4

Input

Gen 1 Lead 4

6

Input

Gen 1 Lead 5

8

Input

Gen 1 Lead 6

10

Input

Gen 1 Lag 1

100

Input

Gen 1 Lag 2

102

Input

Gen 1 Lag 3

104

Input

Gen 1 Lag 4

106

Input

Gen 1 Lag 5

108

Input

Gen 1 Lag 6

110

Input


Table 2. Alarm Registers

Gen 1 Lead Alarm 1

0

Discrete

Gen 1 Lead Alarm 2

1

Discrete

Gen 1 Lead Alarm 3

2

Discrete

Gen 1 Lead Alarm 4

3

Discrete

Gen 1 Lead Alarm 5

4

Discrete

Gen 1 Lead Alarm 6

5

Discrete

Gen 1 Lag Alarm 1

6

Discrete

Gen 1 Lag Alarm 2

7

Discrete

Gen 1 Lag Alarm 3

8

Discrete

Gen 1 Lag Alarm 4

9

Discrete

Gen 1 Lag Alarm 5

10

Discrete

Gen 1 Lag Alarm 6

11

Discrete

Gen 1 Master Alarm

998

Discrete

Gen 1 Processing Errors

999

Discrete

Gen 2 Lead Alarm 1

1000

Discrete

Gen 2 Lead Alarm 2

1001

Discrete

Gen 2 Lead Alarm 3

1002

Discrete

Gen 2 Lead Alarm 4

1003

Discrete

Gen 2 Lead Alarm 5

1004

Discrete

Gen 2 Lead Alarm 6

1005

Discrete

Gen 2 Lag Alarm 1

1006

Discrete

Gen 2 Lag Alarm 2

1007

Discrete

Gen 2 Lag Alarm 3

1008

Discrete

Gen 2 Lag Alarm 4

1009

Discrete

Gen 2 Lag Alarm 5

1010

Discrete

Gen 2 Lag Alarm 6

1011

Discrete

Gen 2 Master Alarm

1998

Discrete

Gen 2 Processing Errors

1999

Discrete


In addition to the input and alarm registers, some overall information about the generators is located in registers as shown in the table below. The registers starting at 8000 are integers, and the ones starting at 8100 are single precision floats.

Table 3. Generator Data Registers

Number of generators

8000

Input

Number of slots per pole for gen 1

8001

Input

Number of slots per pole for gen 2

8002

Input

...

...

Input

Max deviation for gen 1

8100

Input

Max deviation for gen 2

8102

Input

...

...

Input