Procedure for measuring current flowing to ground from the shaft.

Ground Current Test Point

The ground current test points are connected to the Hall effect sensor drivers.

To measure current flowing to ground from the shaft

  1. Set an oscilloscope or digital voltmeter to measure in the mV scale. 

  2. Place the positive and negative probes on the Ground Current + and - test points, respectively.

  3. Refer to the following table to interpret that voltage reading as an associated current value.

Ground_Current_Test_Points.png

Meter Reading (V)

Associated Current (A)

0

0

0.03

1

0.06

2

0.15

5

0.30

10