Related Products:

EGMA-004, EGMA-005, EGMA-006, EGMA-007, EGMA-008, EGMA-013, EGMA-015, EGMA-016, EGMA-019

Related Documents:

EZDP-2020 and EZDP-2038

Type:

Technical information

Keywords/Labels:

Premium Monitoring System, Ground Current, Shaft Voltage,

Summary:

The following article contains information and a table regarding monitoring the Premium Monitoring System for any significant changes in scan rate or attenuation ratio that may require maintenance.

Monitored Lines and Scan Rates

Monitored Line

Scan Rate in Monitoring Mode

Scan Rate for 6-Hour Snapshots

Attenuation Ratio

Ground current

1 MS/second

20 MS/second

50 A : 10 V

Shaft voltage

1 MS/second

20 MS/second

100 V : 10 V

Exciter shaft voltage

(EZDP-2038)

50 MS/second

100 V : 10 V

Shaft metering rope wear indicator

100 kS/second

100 kS/second

100 V : 10 V

Ground rope wear indicator

100 kS/second

100 kS/second

100 V : 10 V

Exciter shaft metering rope wear indicator

(EZDP-2038)

100 kS/second

100 V : 10 V

When live, hourly, and daily values trend outside the norm of the longer-term averages. This indicates that changes are taking place in the generator’s operation. Changes in trending values may be an indicator to manually record and download a new set of waveform snapshots for comparison against past waveforms collected. The information and ratios revealed in these waveforms can potentially assist in identifying the root cause of the change and can be used by trained individuals to identify potentially significant changes taking place in the generator’s bearings, windings, insulation, or other key components.